Scanning with Multiple Focus Scanners Simultaneously in BuildIT
Overview
BuildIT allows the user the ability to work with multiple scanners simultaneously.
Communication between BuildIT and the scanners can be achieved via Wi-Fi.
It can also be achieved via a Ethernet cable, using the Automation Adapter and a Automation Ready Focus Scanner.
The Automation Adapter is also needed when any of the following condition has to be met:
- An Ethernet connection is required (Example: Wi-Fi restrictions).
- The scanner is running at a stationary location, for extended period of time, and needs to remain powered on.
- The scanner needs to be mounted at a repeatable position and angle.
- There is a need to control the scanner directly using the SDK (Example: Utilizing a COM Port for triggering the scanner).
Mechanical Setup
Start by removing the automation cover from the Focus using a star key.
Make sure the cover is fully unscrewed before removing it. |
The Automation Adapter has a screw on the inside, that attaches to the FARO Focus Scanner, using an Allen Wrench.
|
To connect the computer and the FARO Focus Automation Adapter:
|
The FARO Automation Adapter has a power option built into the side. This power source is typically utilized when the Scanner is being mounted at a stationary location and requires constant power.
It is also possible to plug-in the power cable from the FARO Focus Scanner directly into the Focus, if power is necessary.
Configure FARO Focus Scanners
|
Configure Computer settings
- Open the Control Panel.
- Click on Network and Internet.
- Click on Network and Sharing Center.
- On the left side panel, click on Change adapter settings.
- Double-click “Ethernet”. A pop-window will open.
- Choose “Internet Protocol Version 4 (TCP/IPv4)” and click on Properties.
- Change your IP Address to a Static IP Address, by selecting “Use the following IP address”.
- The IP Address will be similar to the Focus LAN IP address, with the exception of the last few digits. Example: 172.17.9.100
- For the last three digits of the IP address, use 100 or any other 2 digit combination. DO NOT use the IP Address being used by the Focus.
- The Subnet mask should automatically populate
Configure Software Settings
- Open BuildIT Metrology
- From the top toolbar navigate to Automate > FARO Focus > Scan using FARO Focus.
- Enter the IP address for each Focus Automation Adapter being used.
- Define your Scan Settings (Resolution, Quality, and Color), if you decide to leave as current, it will use the individual FARO Focus Scanners Settings
- Under Import Options, define the following settings.
- Check Detect Spheres and/or Checkerboards (If utilizing either targets)
- Enter the Sphere Radius (If utilizing Spheres)
- If you want to use a Distance Filter, check Distance Filter, and define the Maximum Distance.
- Click the Checkmark to begin scanning.
When using Targets for registration, a Bundle Registration is recommended after the automation program has processed and registered the scans.
- From the top toolbar, click Align, then click on Bundling Registration.
- Click “All” under Devices and Points.
- Delete the individual scans that were imported with the targets.
- To delete the scans, highlight the individual scan name and press the delete key.
- Under Network final position, select Stationary device.
- Click the Checkmark, to solve the alignment.
- The Bundle Registration Results will appear with your Target Registration error. Review the RMS error and if this is within your desired tolerance, click the Checkbox to save the alignment.